PROJECT OVERVIEWMIXED MODE SYSTEMPROJECT TEAMSOURCES
Name
Country
State
City
Date
Built
Building
Type
Owner
Mixed Mode
Classification
Building System Notes
Architect(s)
Engineer(s)
Web Link
Web Link 2
250 EmbarcaderoUSCASan Francisco2001CommercialThe GapClassification Not FoundNo Building System NotesRobert Stern Architects and Gensler AssociatesKeen Engineering
C&B Engineers
Taylor Engineering
Web LinkNone
30 The Bond at Hickson RoadAustraliaNSWSydney (Millers Point)2003OfficeDeutsche Office TrustcomplementaryChilled beam A/C; operable louvers; 8-story atriumLend Lease/PTW ArchitectsChe WallWeb LinkWeb Link 2
700 Collins StreetAustraliaVictoriaMelbourne (Docklands)2004Mixed UseFolkestone Ltd. and Leighton Properties Pty Ltd.complementaryNo Building System NotesBligh Voller Nield/Peddle Thorp.Gutteridge, Haskins & Davey Pty Ltd.Web LinkNone
Alum Rock Youth CenterUSCASan Jose2003PublicCity of San JoseClassification Not FoundNo Building System NotesBOORA Architects, Inc.Glumac International (Portland)Web LinkNone
Applied Computing & Engineering Sciences BuildingCanadaONPeterborough AcademicSir Sandford Fleming Collegeconcurrent/changeover (?)Integrated management system;3 thermal chimneys; operable windows/clerestory reliefLine Architecture Inc.Keen EngineeringWeb LinkWeb Link 2
Ash Creek Intermediate SchoolUSORMonmouth2002K-12Central School District 13Jzoned/alternateGravity roof vents provide natural cooling and ventilation, with only occasional support from VAV fans.BOORA Architects, Inc.EESI
Systems West Engineers
Eugene (commissioning)
Web LinkWeb Link 2
Ashburton Grove - Arsenal StadiumUK London EventArsenal FCcomplementaryNo Building System NotesHOK SportUnknownWeb LinkNone
Aspect CommunicationsUSCASan Jose2001CommercialAspect Communications Corp.Classification Not FoundUnderfloor air distribution system; operable windowsMcDonough/Form4Critchfield Mechanical, Inc. (CMI)Web LinkNone
Audubon Center at Debs ParkUSCALos Angeles2003InstitutionalNational Audubon SocietyClassification Not FoundOperable windows; clerestory ventilation; 100% solar-powered heating and cooling. Efficient fans for contingency ventilation.Esherick Homsey Dodge & DavisIBE Consulting Engineers
CTG Energetics, Inc. (commissioning and LEED consultant)
Web LinkWeb Link 2
Bang and Olufsen HQDenmark Struer1998CommercialBang and Olufsenalternate (?)No Building System NotesKHR Architects A/SBirch and Krogboe A/SWeb LinkNone
Barclaycard HeadquartersUK Northampton1996CommercialBarclays Property Holdings Ltd.complementaryNo Building System NotesFitzroy Robinson Ltd.Troup Bywaters + AndersWeb LinkNone
Barclays, Gloucester Business ParkUK Basildon OfficeBarclays Group Property Servicescontingency/zonedNo Building System NotesFitzroy Robinson Ltd.Troup Bywaters + AndersWeb LinkNone
Belvedere Court at the Shell CenterUK London CommercialBovis Lend Lease and Shell InternationalClassification Not FoundNo Building System NotesOve Arup and PartnersOve Arup and PartnersNoneNone
Blythe Valley Park Campus-Ove Arup and Partners Midlands OfficeUK Midlands2002CommercialBVP Developments.alternateNo Building System NotesOve Arup and PartnersOve Arup and PartnersWeb LinkNone
Bournemouth Central LibraryUK Bournemouth PublicBournemouth Borough CouncilcomplementaryNo Building System NotesBournmouth Borough CouncilUpton McGougan/IEI Ltd.Web LinkNone
Bren School of Environmental ManagementUSCASanta Barbara2002AcademicUniversity of California, Santa Barbaraconcurrent/changeoverNatural flow-through transom ventilation and operable windows in offices; high-efficiency chillerZimmer Gunsul Frasca PartnershipFlack & Kurtz Consulting EngineersWeb LinkWeb Link 2
BT BrentwoodUK Brentwood2000CommercialBritish Telecommunications plczoned/changeoverNo Building System NotesUnknownOve Arup and PartnersWeb LinkNone
Building 850USCAPort Hueneme2001Military MixedUnited States NavyClassification Not FoundOperable windows along east-west axis; natural gas heat pump A/C, VAV underfloor air distributionScott Ellinwood and AssociatesRBF ConsultingWeb LinkNone
c/PLEX Art CenterUK Sandwell2005InstitutionalJubilee Artschangeover/concurrentIntelligent façade: NV and nighttime coolingWill AlsopBattle McCarthyWeb LinkNone
C21 TowerAustraliaVictoriaMelbourne   Classification Not FoundNo Building System NotesGrey PuksandUnknownWeb LinkNone
Caisse de Depots et de Placements du Quebec CanadaQCMontreal2002CommercialCaisse de Depots et de Placements du Quebec Classification Not FoundNo Building System NotesGauthier, Daoust, Lestage/Faucher, Aubertin, Brodeur, Gauthier, Lemay et associésAndre Potvin, Univ. of LavalWeb LinkNone
Carnegie Institute Center for Global EcologyUSCAPalo Alto AcademicStanford Universityzoned/concurrentThe center’s functions were zoned into separate categories requiring different levels of ventilation and cooling. Offices can be naturally ventilated, while lab functions require high levels of ventilation and cooling. Esherick Homsey Dodge & DavisRumsey EngineersWeb LinkWeb Link 2
CBF Merrill Environmental CenterUSMDAnnapolis2000NGOChesapeake Bay FoundationchangeoverTemperature and humidity sensors located on the exterior of the building determine when the climate is appropriate for natural ventilation. Upon sensing optimal conditions the building management system turns off the mechanical heating or cooling system and turns on modified exit lighting fixtures which notify the building occupants that it is ok to open the windows. Simultaneous to this change mechanical operators open the windows in the clerestory above the second floor to allow a natural draft to begin. Air is then pulled in though the operable windows, rises through the building, and exits through the clerestory.SmithGroup, Inc.SmithGroup, Inc.Web LinkNone
Center for Environmental Urban Studies Demonstration HouseUSCASanta Monica Academic RenovationSanta Monica CollegecontingencyOperable windows, ventilation tower/hot air vent;Duvivier ArchitectsUnknownWeb LinkNone
Center for Japanese Studies, University of IndonesiaIndonesia West Jawa1995AcademicUniversity of IndonesiazonedNo Building System NotesAkihiko TakeuchiUnknownNoneNone
Centre for Mathematical Sciences, University of CambridgeUK Cambridge AcademicUniversity of Cambridgezoned/changeoverSingle-sided NV and displacement ventilation; time-controlled systems; NV for night coolingEdward Cullinan ArchitectsRoger Preston & PartnersWeb LinkNone
Charles Sturt University, Thurgoona Campus AustraliaNSWAlbury2001AcademicCharles Sturt UniversityClassification Not Foundnight cooling through automatic operation of low and high level louver vents; TM façade cooled by water flow; thermal chimneys and clerestories for stack ventilation; operable windowsCharles Sturt University Office of DesignUnknownWeb LinkNone
Chicago Center for Green TechnologyUSILChicago2002PublicCity of Chicago Department of Environmentzoned/concurrentAs a 1950s office building, the structure had been designed for natural cross ventilation as well as daylighting using narrow wings extending out from a common circulation core. The renovation took advantage of this existing condition to retain operable windows while adding a mechanical cooling system.Farr AssociatesIBC EngineeringWeb LinkNone
City of Melbourne Council House 2 (CH2)AustraliaVictoriaMelbourne2005PublicCity of MelbournechangeoverNighttime flushingMick Pearce/Design Inc.Lincolne Scott Consulting EngineersWeb LinkNone
Clackamas High SchoolUSORClackamas2002K-12North Clackamas School District No. 12zoned/alternateMechanically controlled dampers, louvers, and air stacks provide natural ventilation and cooling to all classrooms, common areas, and gymnasiums. Air conditioning is only provided for year-round use areas, such as the media center, administrative spaces, the counseling wing, and the theater, with the capability to transfer cooling to any other selected areas as needed. Control system monitors outdoor and room temperature, CO2 levels, and occupancy status and shuts off mechanical system at pre-defined set-points. (source: USGBC) BOORA Architects, Inc.CBG Consulting Engineers
Interface Engineering, Portland (commissioning)
Web LinkWeb Link 2
CNA-SUVA Building Switzerland Basel1993CommercialCNA-SUVAchangeoverRenovation of low-rise office bldg/addition of prismatic panels; middle windows are occupant controlled; lower windows are auto-controlled for seasonal/diurnal heat retentionHerzog and DeMeuron UnknownWeb LinkNone
Cologne BuildingGermany Frankfurt   Classification Not FoundNo Building System NotesUnknownUnknownNoneNone
Commerzbank HeadquartersGermany Frankfurt1997CommercialComerzbank (?)changeoverNV most of year; chilled ceiling cooling in summerNorman Foster and PartnersOve Arup and PartnersWeb LinkNone
Cooperative Retail Services (CRS) HQUK Rochdale1994CommercialCo-operative Retail Services Ltd.concurrent/zonedchilled beams/displacement ventilation systems; deep-plan floorplates/3 central atriums; conventional AHUs and packaged chillers; 100% fresh air ventilation; 3 zones for A/C; BEMS controls all main plantTaylor Young PartnershipHoare Lea & PartnersWeb LinkWeb Link 2
Copenhagen Opera HouseDenmark Copenhagen2005PublicA.P. Møller and Chastine McKinney Møller FoundationClassification Not FoundFloor heating and cooling in foyer;Henning Larsens TegnestueRambøll A/SWeb LinkWeb Link 2
Crown Hall Renovation, University of IL ChicagoUSILChicago2005Academic RenovationIllinois Institute of TechnologyClassification Not FoundMM is original to building design (NV plus forced hot air); historic retrofit added ceiling diffusers for return and supply; current renovation includes automation of ventilation flaps and improved control of radiant floor systemMies van der Rohe
Kruek & Sexton
McClier (renovation)
Atelier TenWeb LinkNone
Crystal Cathedral Int'l Center for Possibility ThinkingUSCAGarden Grove2003InstitutionalCrystal Cathedral MinistriescomplementaryNV through atrium with supplemental AC for peak conditions; NV optimized by CFD modelingRichard Meier & PartnersSyska Hennessy Group,Web LinkNone
CSIRO Energy CenterAustraliaNSWNewcastle2003Laboratory/OfficeCSIRO Energy Technologychangeover/concurrentBMS; indoor screen display advises occupants of when to open/close windows; underfloor air distributionCox Richardson ArchitectsFlack & Kurtz Consulting EngineersWeb LinkWeb Link 2
Dana Hall, University of Michigan USMIAnn Arbor2002AcademicUniversity of MichiganClassification Not FoundChilled ceiling with conditioned ventilation airN/AOve Arup and Partners
Timmons Design Engineers
Web LinkNone
David L. Lawrence Convention CenterUSPAPittsburgh2003EventSports and Exhibition Authority of Pittsburgh and Allegheny CountychangeoverSloped roofs channel NV off river; AHUs shut off when outside temperatures fall below 65 degrees F; nighttime NV used for cooling; fabric ductsRafael Viñoly and Burt Hill Kosar RittelmannBurt Hill Rittelmann Associates,Web LinkWeb Link 2
debis HeadquartersGermany Berlin1997CommercialDaimler Benz Inter Servicesconcurrent (?)No Building System NotesRenzo Piano/Christoph KohlbeckerUnknownWeb LinkNone
Department for the Environment/Food and Rural AffairsUK Temple Quay, Bristol  InstitutionalDepartment of the EnvironmentconcurrentAir-cooled water chiller serves underfloor air system that supplements NV in summerUnknownWSP GroupWeb LinkNone
Don & Low Ltd. Textile Manufacturing FacilityUK Forfar2001IndustrialDon & Low Ltd.complementaryNo Building System NotesUnknownEnConsultWeb LinkWeb Link 2
Doncaster Earth CentreUK Doncaster OfficeEarth CentreClassification Not Foundstack and displacement ventilation; cooled floorsFeilden Clegg Bradley Architects LLPAtelier TenWeb LinkNone
Dulwich CollegeUK London2005AcademicDulwich CollegecomplementaryNo Building System NotesUnknownTroup Bywaters + AndersWeb LinkNone
Düsseldorf Stadttor (City Gate)Germany Düsseldorf1997Commercial changeoverNV 60% of the yearPetzinka, Pink & Partners UnknownWeb LinkNone
EdF-SEISO Regional HeadquartersFrance Bordeaux1996PublicElectricite de FranceClassification Not FoundNo Building System NotesFoster and PartnersUnknownNoneNone
Edinburgh Gate-Addison Wesley Longman HQUK London (Harlow)1995CommercialHypobankzoned2 300-kW chillers serve restaurants and meeting rooms; stack ventilation, operable windows within office areasCD PartnershipCundall Johnston & PartnersWeb LinkNone
Elizabeth Fry Building, University of East AngliaUK Norwich1995AcademicUniversity of East AngliaconcurrentNo Building System NotesJohn Miller and PartnersFulcrum ConsultingWeb LinkNone
e-Science facility, University of Newcastle upon TyneUK Newcastle upon Tyne 2004AcademicUniversity of NewcastleClassification Not FoundNo Building System NotesUnknownUnknownNoneNone
EurotheumGermany Frankfurt1999Mixed Use Classification Not FoundNo Building System NotesNovotny Mähner + AssociatesUnknownWeb LinkNone
Faculty of Management and DesignUK Aberdeen1998AcademicRobert Gordon UniversitychangeoverNo Building System NotesFoster and PartnersHulley and Kirkwood Consulting EngineersWeb LinkNone
Federal Building San FranciscoUSCASan Francisco2006Public/OfficeGeneral Services Administrationchangeover/concurrent/zoned70% of structure to be cooled with NV; remote-controlled façade apertures activated for nighttime cooling of concrete structure; fluted concrete floors enhance air flow; underfloor air distribution systemMorphosis and SmithGroup, Inc.Ove Arup and Partners (Los Angeles)
NaturalWorks (NV modeling)
Web LinkWeb Link 2
Fisher Pavilion at Seattle CenterUSWASeattle2002AssemblySeattle Center and City of SeattlechangeoverUse of ceiling destratification fans to redistribute heat; constant volume ventilation system; NV through operable garage doorsMiller/Hull PartnershipThe Greenbusch Group, Inc.Web LinkNone
Fox Studios Child Development CenterUSCALos Angeles2000CommercialFox StudioschangeoverNV plus high efficiency HVAC for peak loadsRios AssociatesSyska Hennessy Group,Web LinkNone
Froude Modeling Hall/HR WallingfordUK Wallingford2004InstitutionalHowbery Park EstatesClassification Not FoundNOT ENOUGH INFO/Building looks like typical warehouse/ceiling duct vents & loading bays, few windowsScott BrownriggUnknownWeb LinkNone
Fujita Technology Development DivisionJapan Atsugi Kanagawa prefecture1999Laboratory/Office changeoverAlternating mech and NV. VAV. NV during non-occupied hours.Fujita CorporationFujita CorporationWeb LinkNone
Gap 901 Cherry St. BuildingUSCASan Bruno1997CommercialThe GapClassification Not FoundCool nighttime air captured in underfloor system and released during the day; operable windowsWilliam McDonough and Partners/Gensler, San FranciscoOve Arup and Partners (San Francisco)Web LinkWeb Link 2
Gates Computer Science BuildingUSCAPalo Alto1996AcademicStanford UniversityClassification Not FoundOperable windowsRobert A.M. Stern Associates/Fong and ChanUnknownWeb LinkNone
Gemeinnützige Siedlungs-und Wohnbaugenossenschaft mBH (GSW) HQGermany Berlin1999CommercialGSWconcurrent (?)No Building System NotesSauerbruch Hutton ArchitektenUnknownWeb LinkNone
Gilman Ordway Building at the Woods Hole Research CenterUSMAFalmouth2003Office/LaboratoryWoods Hole Research Center CorporationzonedRadiant heating and cooling; valence convectors for individual zoned controlWilliam McDonough and Partners2rw Consulting EngineersWeb LinkNone
Government of Canada Office BuildingCanadaPEICharlottetown2005PublicPublic Works and Government Services CanadaClassification Not FoundNo Building System NotesBergmark, Guimond, Hammarlund, Jones Architects
HOK/Urbana Architects
UnknownWeb LinkNone
Granta Park/Millenium Pharmaceuticals (?)UK Cambridge Commercial S+TTWI/MEPC LimitedClassification Not FoundThis is an entire office park; not clear which building is MM.UnknownUnknownNoneNone
Green on the GrandCanadaONKitchener Spec. OfficeIan Cook Construction Ltd.Classification Not Foundceiling radiant cooling and heating; energy-efficient AHU; UnknownEnermodal EngineeringWeb LinkNone
Grove House, Thames Valley UniversityUK London2001Academic RenovationThames Valley Universityconcurrent/changeoverOperable windows; nighttime flushingThames Valley University EstatesPassivent Ltd, Thames Valley University EstatesWeb LinkNone
Halliburton Hill Park Office Complex/Brown & Root HQUK Leatherhead1997CommercialHaliburton Companychangeover/concurrentLow level windows/manually operable; external sensors close high level windows automatically and operate extraction fans during bad weatherBlair Associates ArchitectureBrown & RootWeb LinkNone
Headquarters Training Command, Victoria BarracksUK Paddington2002MilitaryDepartment of Defense-Corporate Services and Infrastructure GroupcomplementaryNo Building System NotesBates SmartHyder ConsultingWeb LinkNone
Honda Northwest Regional FacilityUSORGresham2001CommercialAmerican Honda Motor Co., Inc. concurrentRaised floor air distribution; NV in office area; gravity turbines assist ventilation; VAV hvac systemGroup MackenzieSystem Design Consultants Inc.
Hatten/Johnson Associates
PECI, Portland, OR (commissioning)
Web LinkWeb Link 2
IBM SariFrance Paris (La Defense)   Classification Not FoundNo Building System NotesUnknownUnknownNoneNone
Illawarra Institute Of Technology Shellharbour CampusAustraliaNSWShellharbour2003AcademicTAFE NSWcomplementary/changeoverNo Building System NotesSuters ArchitectsUnknownWeb LinkNone
Imperial War Museum NorthUK Manchester2002PublicThe Trustees of the Imperial War Museum, London, Englandcomplementary/zonedNo Building System NotesDaniel LibeskindMott MacDonaldWeb LinkWeb Link 2
Information Services Building (ISB), University of OtagoNew Zealand Otago2002AcademicUniversity of OtagozonedAutomatically controlled operable windows; zoning; exposed TM; mech cooling to 15% of buildilng, NV for restOpus Consultants & Hardy Holzman PfeifferUniversity of Otago staffWeb LinkNone
Inland Revenue Centre UK Nottingham1994Commercial concurrentNo Building System NotesMichael Hopkins & Partners Ove Arup and PartnersWeb LinkNone
Innovation Park/St. John's HouseUK Cambridge1994CommercialSt. John's College, CambridgeClassification Not FoundNo Building System NotesRH PartnershipBattle McCarthyWeb LinkNone
Institute of Languages building, University of NSWAustraliaNSWSydney2000AcademicUniversity of NSWcomplementaryOperable windowsJackson Teece Chesterman WillisSteensen VarmingWeb LinkNone
Investa Property Group - 126 Phillips St.AustraliaNSWSydney2005CommercialBovis Lend-LeaseClassification Not FoundNo Building System NotesFoster and PartnersUnknownNoneNone
IVEG BuildingBelgium Hoboken1999officeIVEGchangeoverNo Building System NotesM. MusscheIVEG and Air-Consult EngineeringWeb LinkWeb Link 2
J. Walter Thompson HeadquartersGermany Frankfurt1996CommercialMichael LoulakisClassification Not FoundNo Building System NotesSchneider and SchumacherUnknownNoneNone
Jean Vollum Natural Capital CenterUSORPortland2001CommercialEcotrustchangeoverOccupancy sensors reduce hvac use when vacant; hvac automatically shuts down when operable windows are openedHolst ArchitectureInterface EngineeringWeb LinkWeb Link 2
Kent County Police Call CentreUK Maidstone2001Public Classification Not FoundNo Building System NotesUnknownUnknownNoneNone
Lakeview Terrace LibraryUSCALA2003PublicCity of Los Angelesconcurrent/changeover80% naturally-ventilated; windows controlled by energy management system; passive cooling tower; night flushing; digital controls direct operation sequence to anticipate cooling needs based on trailing weather data; manual override capabilityFields Devereaux Architects & EngineersFields Devereaux Architects & Engineers
GreenWorks LA (IEQ and energy consulting)
Web LinkNone
Lewis Center for Environmental StudiesUSOHOberlin2000AcademicOberlin CollegezonedRadiant floor and passive solar heating; thermal mass moderates building temperature; decentralized hvac; water source heat pumps coupled to energy recovery ventilatorsMcDonoughLev Zetlin AssociatesWeb LinkNone
Lillis Business Complex, University of OregonUSOREugene2003AcademicUniversity of OregonzonedOperable vents for NV; thermal mass; half of offices cooled only by NV and fans; nighttime cooling through atriumSRG PartnershipBalzhiser & Hubbard Engineers
SolArc Architecture & Engineering (commissioning)
Web LinkNone
Manor Park/Rare HeadquartersUK Twycross1999CommercialRare Ltd.changeover/concurrentclerestory and stack ventilation BEMS-controlled windows with manual override; operable windows at office level; BEMS (building energy management system)-controlled night cooling/concrete ceilings (TM); BEMS-controlled individual fan units at floor level with manual override (borehole-cooled); recirc. heatingFeilden Clegg Bradley Architects LLPBattle McCarthyWeb LinkNone
Matsuchita ElectronicJapan Shinagawa1996CommercialMatsuchita Electric Co. Ltd.Classification Not FoundNo Building System NotesNikken Sekkei Ltd.UnknownNoneNone
McCormick Tribune Campus Center IITUSILChicago2002AcademicIllinois Institute of TechnologyClassification Not FoundNo Building System NotesRem KoolhaasSOM,Web LinkNone
Mithun Partners Office - Pier 56USWASeattle2000CommercialMartin Smith Inc.contingency (?)Operable windows; passive cooling, primarily through roof; no mechanical coolingMithun PartnersHoladay Parks
Keen Engineering (hvac consultant)
Web LinkWeb Link 2
National Assembly for Wales Assembly BuildingUKWalesCardiff2005PublicNational Assembly of WalesClassification Not FoundNo Building System NotesRichard Rogers PartnershipOve Arup and PartnersWeb LinkNone
National Library Board Building Singapore Singapore2004InstitutionalNational Library Boardconcurrent/zonedNV supplemented by fans in public spaces; airflow and energy simulations doneT.R. Hamzah and Yeang International Buro Happold SingaporeWeb LinkNone
Natural Resources Defense CouncilUSCASanta Monica2003InstitutionalThe Natural Resources Defense Council (NRDC)concurrent (?)An integrated design, incorporating operable windows, skylights, and clerestories, brings fresh air and natural daylight into the working space and offers views of the outdoors. A climate control system maintains optimal indoor conditions while minimizing energy use. Moule & PolyzoidesSyska Hennessy Group,Web LinkNone
New HQ for the Department of Arts, Heritage, Gaeltacht and the IslandsIreland Dublin PublicDepartment of Arts, Heritage, Gaeltacht and the Islandsconcurrent (?)Single sided ventilation; cross and stack ventilation; atrium ventilation; trickle ventilation; night cooling; BMS weather compensatedde Blacam and Meagher ArchitectsMax Fordham llp.Web LinkNone
New Student Services CentreAustraliaNSWCallaghan 2001Academic RenovationUniversity of Newcastlechangeoveradaptive re-use of Hunter Gymnasium; MM allows NV on average temperature days and reverts to A/C for extreme conditions; BMS based on exterior temperature sensorsUniversity Architects/Shaddock Smith ArchitectsUnknownWeb LinkNone
NFU Mutual and Avon GroupUK  1983Commercial concurrentNo Building System NotesMatthew Marchall & PartnersUnknownNoneNone
Nicola Valley Institute of TechnologyCanadaBCMerritt2002AcademicNicola Valley Institute of Technology/University College of the Caribooconcurrent (?)ventilation stack; user controlled operable windows; sensored motorized atrium windows; relief grills between rooms and atria; TM/nighttime flushingBusby + Associates ArchitectsKeen EngineeringWeb LinkWeb Link 2
Nottingham University Jubilee CampusUK Nottingham1999AcademicUniversity of NottinghamchangeoverLake and tree belts as microclimate modifiers; E-plan; fan-assisted solar power ventilation; orientation facilitates wind capture; goal is "to achieve level of 20% of ventilation energy demand of a comparable (BRE Standard) building"; 100% outside air, .5 cfm/ft2 can be doubled for nighttime flushing; raised floor plenums/atria; exhaust-side evaporative cooler provides 10 degrees natural cooling along with TM and nighttime flushing; There is a control mode that allows full natural ventilation using windows to introduce fresh air, and relying on the stack effect to exhaust. Barry Smith noted that this was not added, or not fully commissioned.Michael Hopkins & Partners Ove Arup and PartnersWeb LinkNone
Number One, Leeds City Office ParkUK Leeds CommercialBritish Gas Propertiesalternate\\Arch1\share\BSG\_CBE\Mixed Mode Case Studies\02 MM General Info\Bill Bordass\GIR056 mixed mode.pdfPeter Foggo AssociatesPeter Foggo AssociatesWeb LinkNone
Oacis Building (Possible Other Owner/per Erik Ring)USCASan Rafael1998Commercial Classification Not FoundNO INFO AVAILABLEUnknownUnknownWeb LinkNone
Ove Arup and Partners OfficeUKWalesCardiff   Classification Not FoundNo Building System NotesUnknownOve Arup and PartnersNoneNone
Oxford Instruments HQUK Abingdon CommercialBarwick Property Consultantsconcurrent/changeoverNighttime cooling; stack and cross ventilation mixed with displacement ventilationMichael Waite Associates Whitby Bird & PartnersWeb LinkNone
Palazzina I GuzziniItaly Recanati1997CommercialI Guzzini ManufacturingchangeoverNo Building System NotesMCA studio, ParisMCA studio, ParisWeb LinkNone
Pennsylvania DEP Cambria Office BuildingUSPAEbensburg2002CommercialMiller Brothers Construction, Inc.Classification Not FoundNo Building System NotesKulp Boecker Architects, P.C.Phoenix Geothermal ServicesWeb LinkWeb Link 2
Phoenix Natural Gas HQ, Sydenham Business ParkIreland Belfast CommercialLattice Property Holdings/Phoenix Natural GasClassification Not FoundNo Building System NotesCartwright Pickard QS Gardiner & TheoboldWeb LinkNone
Pierce County Environmental Services BuildingUSWAUniversity Place2002Public/OfficePierce County Environmental ServiceschangeoverRaised floor plenum; nighttime flushingMiller Hull Architects, SeattleAE AssociatesWeb LinkNone
Powergen Corporate HQUK Coventry1995CommercialPowergen plcchangeover/zonedComputer suite A/C 24 hrs/dayBennetts AssociatesErnest Griffiths & SonWeb LinkWeb Link 2
Red Kite House/The Environment AgencyUK Wallingford2005InstitutionalHowbery Park Estateschangeover (?)NV for summer seasonScott BrownriggHoare Lea & Partners,Waterman PartnershipWeb LinkWeb Link 2
Refuge HouseUK     concurrentNo Building System NotesUnknownUnknownNoneNone
Reid Associates Office/West End House, 11 Hills PlaceUK London2001Commercial Renovation complementaryNo Building System NotesReid AssociatesCharterhouse Group
Machenair Ltd.
Web LinkNone
Renovation/Expansion People's Food Co-op USORPortland2003RetailPeople's Food Co-OpchangeoverPassive ventilation; night flushing; stack ventilation with mechanical fan assist; radiant slab cooling activated by thermostat setpoint; windows closed manually if outdoor temperature rises above desired indoor temperatureDave Wadley/Cynthia BankeySOLARC Architecture and Engineering, Inc.Web LinkNone
Roden Crater ObservatoryUSAZFlagstaff Public Classification Not FoundUnderground visitors' center/exhibition space; long-term projectSOM NY/James TurrellSOM,NoneNone
RWE AG HeadquartersGermany Essen1997CommercialHochtief AGchangeoverDouble-skin façadeIngenhoven, Overdiek Kahlen und PartnerUnknownWeb LinkNone
Sainsburys Millennium StoreUK London1999RetailJ Sainsbury plcconcurrentClerestory convective ventilation; radiant cooling/heating; local underground water cools food refrigeration; concrete construction/TMChetwood AssociatesCharterhouse GroupWeb LinkNone
Salem Conference CenterUSORSalem2004EventCity of SalemcomplementaryCross ventilation plus radiant heating and coolingLMN ArchitectsInterface EngineeringWeb LinkNone
San Mateo County Forensics LabUSCASan Mateo2003PublicSan Mateo CountyzonedNo Building System NotesHOKHOKWeb LinkNone
Science Park GelsenkirchenGermany Gelsenkirchen1995Commercial S+TLand Nordrhein-WestfalenchangeoverBuilding management computer cuts of heating when flaps are opened.Kiessler+PartnerUnknownWeb LinkNone
Scottish Widows Edinburgh HQUKScotlandEdinburgh 2001OfficeScottish Widows Fund and Life Assurance SocietycomplementaryNo Building System NotesBuilding Design Partnership Cundall Johnston & PartnersWeb LinkNone
Seattle Northeast Branch LibraryUSWASeattle2004Public/ExpansionCity of SeattlecomplementaryNaturally ventilated with mechanically controlled windows; mention of ductworkMiller Hull Architects, SeattleUnknownWeb LinkNone
Seminar Two Building USWAOlympia2004AcademicThe Evergreen State CollegezonedNV chimneys for each of 8 clusters; lower floors mechanically cooled; nearly 80% NVMahlum Architects, SeattleWood/Harbinger, IncWeb LinkNone
Simmons Hall, MITUSMACambridge2002HousingMassachusetts Institute of Technologycomplementary3000+ operable windows; TM; plus student rooms not occupied during summer (lowers need for cooling); ET+A software used; each room has 9 operable windows, low and high for convective ventilation; low-volume ducted A/C system;Steven HollOve Arup and PartnersWeb LinkNone
SMUD Customer Service CenterUSCASacramento1996OfficeSMUDchangeoverUnderfloor air; chiller; operable windows; designed to maintain slightly positive pressure to ensure exfiltration so that only conditioned air is supplied to the occupied space; operable windows are equipped with micro-switch sensors to reset operation of the adjoining VAV box to night setback mode (increase cooling and decrease heating setpoints) when windows are openWilliams + PaddonHensel Phelps,Robert Bein, William Frost, & AssociatesWeb LinkNone
South Cambridgeshire District Council HeadquartersUK Cambourne, Cambridge 2004CommercialSouth Cambridgeshire District Council (?)changeoverNo Building System NotesAukett EuropeUnknownWeb LinkNone
Stella HouseUK Newcastle upon Tyne  OfficeOne NorthEast complementaryNo Building System NotesRed Box Design Group RW GregoryWeb LinkNone
Surrey Tax CentreCanadaBCSurrey1998PublicPublic Works and Government Services Canadachangeoverdisplacement ventilation with 100% fresh air; periods of free coolingBusby + Associates ArchitectsKeen EngineeringWeb LinkNone
Swiss Re HeadquartersUK London2004CommercialSwiss Reinsurance CompanychangeoverBuilding profile creates external pressure differentials that drive 'unique' natural ventilation system; stack ventilation through atria along skin/window openings; also A/C; CFD and Dynamic Thermal Modeling used; NV used for up to 40% of year/otherwise sealed for A/C.Foster and PartnersHilson Moran Partnership Ltd.Web LinkNone
The Body Shop OfficesUK Littlehampton1991CommercialThe Body Shop International plc/Store Property InvestmentscontingencyBREEAM rating; cross-ventilation due to location, "free cooling"; gas-fired boilerMichael Cook AssociatesWSP Consulting EngineersWeb LinkNone
The Brewery Blocks-Brewery Block 4USORPortland2003Mixed UseGerding/Edlen Development Company, LLCcomplementaryNo Building System NotesGBD Architects Inc.Glumac InternationalWeb LinkNone
The Liberty Tower of Meiji UniversityJapan Tokyo1998Academic changeoverNo Building System NotesNikken Sekkei Ltd.Nikken Sekkei Ltd.Web LinkNone
Thoreau Center for SustainabilityUSCASan Francisco1986NGO/OfficeThe Presidio Trust (?)contingencyNo Building System NotesLeddy Maytum Stacy ArchitectsFlack & Kurtz Consulting EngineersWeb LinkNone
Tokyo Gas Earth PortJapan Yokohama, Kanagawa-ken1996Commercial changeoveratrium as temperature control; alternating mechanical and stack and wind-driven NV; auto control of façade and stack openings; A/C for remaining hoursNikken Sekkei Ltd.Nikken Sekkei Ltd.Web LinkWeb Link 2
Toyo Village Mason MuseumJapan Kumamoto Prefecture1993InstitutionalToyo VillageClassification Not FoundNo Building System NotesYasufumi Kijima & Yas and UrbanistsUnknownNoneNone
Trade Associates Group HQUSILChicago CommercialTrade Associations GroupClassification Not FoundNo Building System NotesStudio Gang O'DonnellBattle McCarthyNoneNone
UCLA Kinsey HallUSCALos Angeles AcademicUniversity of California, Los AngelescomplementaryChilled ceiling with mechanical and natural ventilationTimmons Design EngineersOve Arup and PartnersWeb LinkNone
UCM Classroom & Office BuildingUSCAMerced2005AcademicUC MercedClassification Not FoundNo Building System NotesThomas Hacker ArchitectsKeen EngineeringWeb LinkNone
UCSC Humanities FacilityUSCASanta Cruz2005AcademicUniversity of California, Santa CruzClassification Not FoundNo Building System NotesThomas Hacker ArchitectsKeen EngineeringWeb LinkWeb Link 2
Ukichiro Nakaya Museum of Snow and IceJapan Kaga, Ishikawa Prefecture1994InstitutionalKaga CityClassification Not FoundNo Building System NotesArata Isozaki and AssociatesUnknownNoneNone
Univ. of Toronto - Bahen Information Technology CentreCanadaONToronto2002AcademicUniversity of TorontoClassification Not FoundNo Building System NotesDiamond and Schmitt Architects IncorporatedKeen EngineeringWeb LinkNone
University of Surrey Management SchoolUK Guildford2003AcademicUniversity of SurreyClassification Not FoundNo Building System NotesUnknownTroup Bywaters + AndersWeb LinkNone
University of York Bioscience DepartmentUK York LaboratoryUniversity of YorkchangeoverA/C including "Category 3" ventilation for fume hoods;UnknownHaden YoungNoneNone
Vice Chancellor's Office, Academie des Antilles et de la GuyaneFrench West Indies Martinique1994AcademicMinistere de l'Education NationalezonedNo Building System NotesChristian Hauvette and Jerome NouelUnknownNoneNone
Washington Veterans Home Skilled Nursing FacilityUSWARetsil2005HealthcareState of WashingtonchangeoverMinimal ducted ventilation; code conflicts averted by demonstrating ability to meet temperature range requirements; air handlers meet min. ventilation requirements when windows are closedNBBJKeen EngineeringWeb LinkNone
Westmont High School Science BuildingUSCASan Jose2004Academic/9-12Campbell Union High School DistrictClassification Not FoundRadiant heating and cooling; CSS AssociatesRumsey EngineersWeb LinkNone
Wilkinson BuildingAustraliaNSWSydney1997Office RenovationUniversity of SydneychangeoverNo Building System NotesUnknownMcConnel, Smith and JohnsonWeb LinkNone
William and Flora Hewlett FoundationUSCAMenlo Park2002CommercialThe William and Flora Hewlett FoundationchangeoverThe operable windows are used as part of the building mechanical system’s optimizer cycle.B.H. Bocook Architects, Inc.Critchfield Mechanical, Inc. (CMI)Web LinkNone
Women's Humane Society Animal ShelterUSPABensalem1994NGOWomen's Humane SocietyClassification Not FoundNo Building System NotesSusan Maxman ArchitectsUnknownNoneNone
Yasuda AcademiaJapan Tokyo1994CommercialYASUDA Mutual Life Insurance CompanyClassification Not FoundNo Building System NotesNikken Sekkei Ltd.UnknownNoneNone
York Univ. Computer Science BuildingCanadaONToronto2001AcademicYork Universityzoned/changeoverTM/operable windows; atria/thermal ventilation stacks; distributed fan coils for severe seasons and NV for shoulder seasonsBusby + Associates ArchitectsKeen EngineeringWeb LinkNone
Zion Comfort StationUSUTSpringdale2000PublicNational Park Serviceconcurrentcool towers draw air through evaporative pads; NV otherwise; Energy Mgt computer controls size of openings at base of towers; operable clerestories/low windows draw NV through; Computer controls clerestoryNPS Denver Service CenterNPS (?)Web LinkNone
Zion Visitor Center USUTSpringdale2000PublicNational Park ServiceconcurrentNo Building System NotesNPS Denver Service CenterNPS (?)Web LinkNone
Center for the Built Environment (CBE) | University of California, Berkeley.
All contents copyright © 2005 The Regents of the University of California. All rights reserved.